Fluke 113 Basic Multimeter

Rs.0

Feel free to contact us:
Mobile: 0344 3813810
True-rms Basic Multimeter designed for basic electrical testsThe Fluke 113 Basic Multimeter gives utility users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems.

The Fluke 113 Basic Multimeter has significant improvements over Fluke’s original 7-600, and other utility multimeters. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity.

The Fluke 113 Basic Multimeter can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this new meter is a must have for the utility users toolbox.

What’s Included:

  • Fluke TL75 test leads
  • Holster
  • Users manual
  • and 9 V battery (installed).

Description

Specifications
VCHECK 1,2
Range 6.000 V
60.00 V
600.0 V
Resolution 0.001 V
0.01 V
0.1 V
Accuracy DC, 45 to 500 Hz:2.0 % + 3
500 Hz to 1 kHz: 4.0 % + 3
Diode test 3
Range 2.000 V
Resolution 0.001 V
Accuracy 2.0 % + 3
Continuity3
Range
Resolution
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer
3
Range 600.0 Ω
6.000 kΩ
60.00 kΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
Accuracy 0.9 % + 2
0.9 % + 1
0.9 % + 1
Capacitance3
Range 1000 nF
10.00 μF
100.0 μF
9999 μF
Resolution 1 nF
0.01 μF
0.1 μF
1 μF
Accuracy 1.9 % + 2
1.9 % + 2
1.9 % + 2
100 μF – 1000 μF: 1.9 % + 2
> 1000 μF: 5 % + 20

Notes:
1 All VChek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2 Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3 After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.

Specifications
Maximum voltage between any terminal and earth ground
600 V
Display
3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature
-10 °C to 50 °C (14 °F to 122 °F)
Storage temperature
-40 °C to 60 °C (-22 °F to 140 °F)
Temperature coefficient
0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating altitude
2,000 m
Storage altitude
10,000 m
Relative humidity
95 % to 30 °C
75 % to 40 °C
45 % to 50 °C
Battery type
9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery life
Alkaline: 300 hours typical, without backlight
Shock
1 Meter drop per IEC 61010-1-2001
Vibration
Per MIL-PRF-28800 for Class 2 instrument
Size (HxWxL)
167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in)
Weight
13.0 oz (404 g)
Safety
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
EMI regulations
Complies with FCC Part 15, Class B
Specifications
VCHECK
Input Impedance (Nominal) ~3 kΩ < 300 pF
VCHECK
Common Mode Rejection Ratio (1 kΩ Unbalanced) > 60 dB at dc, 50 or 60 Hz
Ω
Open Circuit Test Voltage < 2.7 V dc
Full Scale Voltage < 0.7 V dc
Diode test
Open Circuit Test Voltage < 2.7 V dc
Full Scale Voltage 2.000 V dc
Short Circuit Current < 350 μA
Diode test
Short Circuit Current < 1.0 mA