Feel free to contact us: Mobile: 0344 3813810 Versatile multimeter for manufacturing, development and service applications
- 5.5 digit resolution
- Basic V dc accuracy of 0.01 %
- Dual display
- Dedicated dc leakage current measurement
- 2×4 ohms 4-wire measurement technique
- Six dedicated buttons for fast access to instrument setups
- Hi/Lo limit compare for Pass/Fail testing
- Meter
- TL71 test leads
- Line cord
- Spare line fuse
- Statement of cal practices
- WEEE information sheet
- Warranty statement
- Getting Started guide (English, French, German, Spanish, Italian, Simplified Chinese, Japanese)
- CD Rom with user manual (English)
-
Feel free to contact us: Mobile: 0344 3813810 Record three-phase power quality and monitor for power quality disturbances with the new Fluke 1750 Three Phase Power Recorder and the Fluke Power Analyzer software. These power meters automatically record every power quality parameter and event, on every cycle – all the time. Never miss capturing a disturbance – with the exclusive threshold-free measurement system, it’s automatic. Capture every measurement, every event, on every cycle, all the time with the Fluke 1750 Three Phase Power Recorder. Unprecedented accuracy and resolution provide complete visibility into your distribution system. The recorder automatically detects, scales, and powers current probes without needing batteries. Requiring only single-lead voltage connections enables safe and quick setups. Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range – no more uncertainty that data is being recorded. The Fluke 1750 Three Phase Power Quality Recorder has an exclusive capture algorithm which makes certain all events are captured without the tedious setups and blind spots associated with threshold driven equipment. The PDA wirelessly interfaces with the recorder, allowing quick setup and verification with waveform displays, meter screens, and phasor diagrams. The built-in wireless technology allows you to control multiple instruments from a distance easily, without the need for a laptop computer (laptops can also be used when desired). Applications: Long-term analysis: Uncover hard-to-find or intermittent issues Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports Quality of service compliance: Validate incoming power quality at the service entrance Semi-permanent monitoring: Monitor critical equipment, capturing power quality events to correlate with equipment malfunctions What’s Included:
- 1750 aquisition unit
- PDA wireless “front panel interface” and charger power plug adapters
- 4 – 400A current probes (3140)
- 5 Test leads and clips
- SD memory card
- Fluke Power View and Fluke Power Analyze software
- Power cord with international plug set
- Ethernet cable
- Color localization set
- Printed Getting Started manual
- Product CD with software and user manual PDF
-
Feel free to contact us: Mobile: 0344 3813810 The Fluke 1740 Series three-phase power quality loggers are everyday power meters for technicians who troubleshoot and analyze power quality issues. Capable of simultaneously logging up to 500 power parameters for up to 85 days and monitoring for events, these power loggers help uncover intermittent and hard-to-find power quality issues. The Fluke 1743 is a powerful three-phase power quality logger capable of logging the most common power parameters you’ll need for power quality monitoring such as:
- V, A, W, VA, VAR
- Power Factor
- Energy
- Flicker
- Voltage
- THD
- The Fluke 1744 includes the same features as the Fluke 1743 but can measure voltage and current harmonics, interharmonics, mains signaling, unbalance and frequency.
- The Fluke 1745 includes the same features as the Fluke 1744 but features an IP50 environmental rating, a real-time LCD display and a 5 hour UPS which is great if you need to read more data at the meter and have a longer backup battery life where there’s less chance of it getting wet.
- Disturbance analysis – Uncover root cause of equipment malfunction for later mitigation and predictive maintenance
- Quality of service compliance – Validate incoming power quality at the service entrance
- Power quality studies – Assess baseline power quality to validate compatibility with critical systems before installation
- Load studies – Verify electrical system capacity before adding loads
- Energy and power quality assessment – Validate performance of facility improvements by quantifying energy consumption, power factor, and general power quality before and after improvements
- 4 Flexible probes 15/150/1500/3000 A with 2 m cable
- CD-ROM with PQ Log software
- RS232 interface cable and RS232-USB adapter
- Test leads for voltages and power supply
- 4 black dolphin clips
- Color localization kit
- Carrying bag
- Test certificate with measurement values
- Printed English manual
- Multi-language manual CD
-
The RDM-3P is fully equipped for testing paperboard, corrugated stock, and paper tubes using its paper scale, 0-100 reference scale, and baled paper scale. Whatever the situation calls for, the RDM-3P delivers. Advanced storage and recall features make it easy to organize multiple jobs, or even download data to a PC via the optional linkage software. The paper production industry has a new ally in the reliable and precise RDM-3P!
-
The CHECK-LINE YSL-2000HD combines the functions of three separate instruments in one, easy-to-use device. It accurately measures the speed and length of yarns, and other filaments using a unique “wrapper” roller. This precision roller directs the filament onto the low-inertia, U-grooved measuring wheel to maximize contact and eliminate filament slip and breakage. The YSL-2000HD can also be used as either a contact or non-contact tachometer to measure rotational speeds of shafts, motors, pulleys, etc. or linear speeds of moving surfaces such as conveyor belts, webs of paper or fabric, etc.
-
Range:0-99,999 Inches or Centimeters The Check-Line LM Series Digital Consumption Meters accurately measure the amount of yarn being fed from a textile machine feeder to a take-up device during one or more cycles or rotations of the machine cylinder. LM units are ideal for comparing yarn consumption from feed to feed and machine to machine on circular and flat bed knitting machines, and for other textile processes where yarn length is to be accurately measured Two LM types are offered: Models LMC and LMI manual type, where operator actuates and deactivates the measuring system after one or more operation cycles. (LMC is calibrated for centimeters; LMI is for inches). The consumption per cycle is then determined by dividing the total yarn consumption by the number of cycles or revolutions Models LMC-S and LMI-S magnetic sensor type, where operator pre-sets number of cycles or revolutions (0-99) for the measuring period, eliminating the need to visually count the number of cycles. A small magnet is affixed to the rotating or moving part of the machine while the sensor is mounted on the frame. Each time the magnetic passes the sensor it actuates the instrument’s electronic counter. Operation – LMI-S / LMC-S In “Auto” mode a permanent magnet is mounted to a revolving part of the machine. The sensor supplies the start/stop signal. The predetermined number of revolutions (from 1- 99 rev. set on the rotary switches at the front side) are counted and the comulated yarn consumption is displayed.
-
Range:0-99,999 Inches or Centimeters The Check-Line LM Series Digital Consumption Meters accurately measure the amount of yarn being fed from a textile machine feeder to a take-up device during one or more cycles or rotations of the machine cylinder. LM units are ideal for comparing yarn consumption from feed to feed and machine to machine on circular and flat bed knitting machines, and for other textile processes where yarn length is to be accurately measured Two LM types are offered: Models LMC and LMI manual type, where operator actuates and deactivates the measuring system after one or more operation cycles. (LMC is calibrated for centimeters; LMI is for inches). The consumption per cycle is then determined by dividing the total yarn consumption by the number of cycles or revolutions Models LMC-S and LMI-S magnetic sensor type, where operator pre-sets number of cycles or revolutions (0-99) for the measuring period, eliminating the need to visually count the number of cycles. A small magnet is affixed to the rotating or moving part of the machine while the sensor is mounted on the frame. Each time the magnetic passes the sensor it actuates the instrument’s electronic counter. Operation – LMI-S / LMC-S In “Auto” mode a permanent magnet is mounted to a revolving part of the machine. The sensor supplies the start/stop signal. The predetermined number of revolutions (from 1- 99 rev. set on the rotary switches at the front side) are counted and the comulated yarn consumption is displayed.
-
Feel free to contact us: Mobile: 0344 3813810
- True-RMS 1000A AC/DC
- Work in tight spots with the 18" iFlex current probe and measure up to 2500A AC
- CAT III/IV Safety ratings
- 3 years Warranty
- CAT IV 600, CAT III 1000 V
- iFlex 2500 A AC
- 1000 V AC/DC
- mV DC
- 60 kΩ
- 1000 μF
- 18-inch iFlex flexible current probe – i2500-18
- TL75 test leads
- Coated instruction card
- Safety information sheet
- Soft carrying case
- Two AA Alkaline batteries
-
Feel free to contact us: Mobile: 0344 3813810
- CAT IV 600
- CAT III 1000 V
- 3 years Warranty
- CAT IV 600, CAT III 1000 V
- iFlex 2500 A AC
- 1000 V AC/DC
- mV DC
- 60 kΩ
- 1000 μF
- 18-inch iFlex flexible current probe – i2500-18
- TL75 test leads
- Coated instruction card
- Safety information sheet
- Soft carrying case
- Two AA Alkaline batteries
-
Feel free to contact us: Mobile: 0344 3813810
- True-RMS
- 600 A AC/DC
- Works with iFlex flexible current probes
- 3 years Warranty
- CAT IV 600, CAT III 1000 V
- iFlex 2500 A AC
- 1000 V AC/DC
- mV DC
- 60 kΩ
- 1000 μF
- 18-inch iFlex flexible current probe – i2500-18
- TL75 test leads
- Coated instruction card
- Safety information sheet
- Soft carrying case
- Two AA Alkaline batteries